Extension module for FXMelsec-F
Extension I/O Module | Model | Inputs Number | Inputs Type | Outputs Number | Outputs Type | Power Supply |
---|---|---|---|---|---|---|
FX2N-8EX-ES/UL | 8 | Sink/Source Selectable | - | - | All extension blocks are powered by the main unit or attached extension unit. | |
FX2N-8EX-UA1/UL | 8 | Sink/Source Selectable | - | - | All extension blocks are powered by the main unit or attached extension unit. | |
FX2N-16EX-ES/UL | 16 | Sink/Source Selectable | - | - | All extension blocks are powered by the main unit or attached extension unit. | |
FX2N-8ER-ES/UL | 4 | Sink/Source Selectable | 4 | Relay | All extension blocks are powered by the main unit or attached extension unit. | |
FX2N-8EYR-ES/UL | - | - | 8 | Relay | All extension blocks are powered by the main unit or attached extension unit. | |
FX2N-8EYT-ESS/UL | - | - | 8 | Source | All extension blocks are powered by the main unit or attached extension unit. | |
FX2N-16EYR-ES/UL | - | - | 16 | Relay | All extension blocks are powered by the main unit or attached extension unit. | |
FX2N-16EYT-ESS/U | - | - | 16 | Source | All extension blocks are powered by the main unit or attached extension unit. | |
FX2N-16EYS | - | - | 16 | Triac | All extension blocks are powered by the main unit or attached extension unit. | |
FX2N-32ER-ES/UL | 16 | Sink/Source Selectable | 16 | Relay | 100-240 VAC | |
FX2N-32ET-ESS/UL | 16 | Sink/Source Selectable | 16 | Source | 100-240 VAC | |
FX2N-48ER-ES/UL | 24 | Sink/Source Selectable | 24 | Relay | 100-240 VAC | |
FX2N-48ET-ESS/UL | 24 | Sink/Source Selectable | 24 | Source | 100-240 VAC | |
FX2N-48ER-DS | 24 | Sink/Source Selectable | 24 | Relay | 24VDC | |
FX2N-48ET-DSS | 24 | Sink/Source Selectable | 24 | Source | 24VDC | |
FX-16E-TB/UL | 16 points (Direct input/output) | 16 points (Direct input/output) | 16 points (Direct input/output) | 16 points (Direct input/output) | - | |
FX-16EYR-TB | - | - | 16 | Relay | - | |
FX-16EYS-ES-TB/UL | - | - | 16 | Triac | - | |
FX-16EYT-TB | - | - | 16 | Sink | - | |
FX-16EX-A1-TB/UL | 16 | 100VAC | - | - | - | |
FX-16E-150CAB | Cable I/O 1.5m | Cable I/O 1.5m | Cable I/O 1.5m | Cable I/O 1.5m | Cable I/O 1.5m | |
FX-16E-300CAB | Cable I/O 3m | Cable I/O 3m | Cable I/O 3m | Cable I/O 3m | Cable I/O 3m | |
FX-16E-500CAB | Cable I/O 5m | Cable I/O 5m | Cable I/O 5m | Cable I/O 5m | Cable I/O 5m | |
FX2NC-16EX-DS | 16 | Sink/Source | - | - | All extension blocks are powered by the main unit or attached extension unit. | |
FX2NC-16EX-T-DS | 16 | Sink/Source | - | - | All extension blocks are powered by the main unit or attached extension unit. | |
FX2NC-16EYT-DSS | - | - | 16 | Source | All extension blocks are powered by the main unit or attached extension unit. | |
FX2NC-16EYR-T-DS | - | - | 16 | Relay | All extension blocks are powered by the main unit or attached extension unit. | |
FX2NC-32EX-DS | 32 | Sink/Source | 8 | Relay | All extension blocks are powered by the main unit or attached extension unit. | |
FX2NC-32EYT-DSS | - | - | 32 | Source | All extension blocks are powered by the main unit or attached extension unit. | |
FX2NC-CNV-IF | Extension blocks converter | Extension blocks converter | Extension blocks converter | Extension blocks converter | All extension blocks are powered by the main unit or attached extension unit. | |
FX-USB-AW | USB interface converter | USB interface converter | USB interface converter | USB interface converter | USB interface converter | |
FX-232-AWC-H | Serial interface converter | Serial interface converter | Serial interface converter | Serial interface converter | Serial interface converter | |
FX3U-FLROM-16 | Memory cassette 16ksteps for FX3U, FX3UC V2.2 or later | Memory cassette 16ksteps for FX3U, FX3UC V2.2 or later | Memory cassette 16ksteps for FX3U, FX3UC V2.2 or later | Memory cassette 16ksteps for FX3U, FX3UC V2.2 or later | Memory cassette 16ksteps for FX3U, FX3UC V2.2 or later | |
FX3U-FLROM-64 | Memory cassette 64ksteps for FX3U, FX3UC | Memory cassette 64ksteps for FX3U, FX3UC | Memory cassette 64ksteps for FX3U, FX3UC | Memory cassette 64ksteps for FX3U, FX3UC | Memory cassette 64ksteps for FX3U, FX3UC | |
FX3U-FLROM-64L | Memory cassette 64ksteps for FX3U, FX3UC V2.2 or later | Memory cassette 64ksteps for FX3U, FX3UC V2.2 or later | Memory cassette 64ksteps for FX3U, FX3UC V2.2 or later | Memory cassette 64ksteps for FX3U, FX3UC V2.2 or later | Memory cassette 64ksteps for FX3U, FX3UC V2.2 or later | |
FX3U-FLROM-1M | Memory cassette 64kstep+1300KB symbolic for FX3U, FX3UC V3.0 | Memory cassette 64kstep+1300KB symbolic for FX3U, FX3UC V3.1 | Memory cassette 64kstep+1300KB symbolic for FX3U, FX3UC V3.2 | Memory cassette 64kstep+1300KB symbolic for FX3U, FX3UC V3.3 | Memory cassette 64kstep+1300KB symbolic for FX3U, FX3UC V3.4 |
Extension I/O module | Model | Inputs | Outputs | Power Supply | ||
---|---|---|---|---|---|---|
Number | Type | Number | Type | |||
FX2N-8EX-ES/UL | 8 | Sink / Source Selectable |
– | All extension blocks are powered by the main unit or attached extension unit. |
||
FX2N-8EX-UA1/UL | 8 | – | ||||
FX2N-16EX-ES/UL | 16 | – | ||||
FX2N-8ER-ES/UL | 4 | 4 | Relay | |||
FX2N-8EYR-ES/UL | – | 8 | Relay | |||
FX2N-8EYT-ESS/UL | – | 8 | Source | |||
FX2N-16EYR-ES/UL | – | 16 | Relay | |||
FX2N-16EYT-ESS/U | – | 16 | Source | |||
FX2N-16EYS | – | 16 | Triac | |||
FX2N-32ER-ES/UL | 16 | Sink/ Source Selectable |
16 | Relay | 100 – 240 VAC | |
FX2N-32ET-ESS/UL | 16 | 16 | Source | |||
FX2N-48ER-ES/UL | 24 | 24 | Relay | |||
FX2N-48ET-ESS-UL | 24 | 24 | Source | |||
FX2N-48ER-DS | 24 | 24 | Relay | 24 VDC | ||
FX2N-48ET-DSS | 24 | 24 | Source | |||
FX-16ETB/UL | 16 points (Direct input / output ) | – | ||||
FX-16EYR-TB | – | 16 | Relay | – | ||
FX-16EYS-ES-TB/UL | – | 16 | Triac | – | ||
FX-16EYT-TB | – | 16 | Sink | – | ||
FX-16EX-A1-TB/UL | 16 | 100 VAC | – | – | ||
FX-16E-150CAB | Cable I/O 1.5m | |||||
FX-16E-300CAB | Cable I/O 3m | |||||
FX-16E-5000CAB | Cable I/O 5m | |||||
FX2NC-16EX-DS | 16 | Sink/Source | – | All extension blocks are powered by the main unit or attached extension unit. |
||
FX2NC-16EX-T-DS | 16 | – | ||||
FX2NC-16EYT-DSS | – | 16 | Source | |||
FX2NC-16EYR-T-DS | – | 16 | Relay | |||
FX2NC-32EX-DS | 32 | Sink/Source | 8 | Relay | ||
FX2NC-32EYT-DSS | – | 32 | Source | |||
FX2NC-CNV-IF | Extension blocks converter | |||||
FX-USB-AW | USB Interface converter | |||||
FX-232-AWC-H | Serial interface converter | |||||
FX3U-FLROM-16 | Memory cassette 16ksteps for FX3U, FX3UC V2.2 or later | |||||
FX3U-FLROM-64 | Memory cassette 64kstep for FX3U, FX3UC | |||||
FX3U-FLROM-64L | Memory cassette 64kstep for FX3U, FX3UC V2.2 or later | |||||
FX3U-FLROM-1M | Memory cassette 64kstep+1300KB symbolic for FX3U, FX3UC V3.0 |
Catalog Name | Download |
---|---|
FX3 Family | Melsec-F Series |
(Visited 410 times, 1 visits today)