CWL Limit Switch

CWL Limit Switch

  • Features
    ♦ Double-circuit type of limit switch. is widely used
    ♦ With strong aluminum case outer shell
    ♦ High mechanical streanth
    ♦ Structure prevending oil , water and pressure
    ♦ Indicating plate with setting position is installed in it, so it is easy to maintain
    ♦ Various of actuators is taken convenience for using
    ♦ Built-it contact stand has double-spring, so it has long mechanical life
  • Contact Form

contact form

  • Characteristics
Operation speed 1mm-2m/s
Operating frequency Mechanical: 120 operations/minute Electical: 30 operations/minute
Contact resistance 15Ωmax.  (Initial value)
 Insulation resistance 100m Ω min. (at 500 VDC)
 Dielectric strength 1000VAC,50/60 Hz for 1 minute between terminal of the same polarity
1500VAC,50/60 Hz for 1 minute between current-carrying and non-current carrying metal parts
1500VAC,50/60 Hz for 1 minute between each terminal and ground
 Vibration 10-55Hz, 1.5mm double amplitude
 Shock  Mechanical durable: 1,000m/Sec(about 100G’S) Malfunction: 300m/Sec2  (about 30G’S)
 Ambient temperature  –
 Humidity <95% RH
 Life Mechanical : 15,000,000 operations above  (under rated OT)

Electrical : 500,000 operations above

Weight About 275g
Degree of Protection  IEC specification : IP67

 

Rated voltage  

Noninductive Load (A)

Inductive Load (A)
Resistance Load Lamp Load Inductive Load Motor Load
NC NO NC NO NC NO NC NO
125VAC 10
5
3
1
3
2
1.5
1
1.5
1
0.8
0.5
10
5
3
1.5
5
3
1.5
1
2.0
1.0
0.8
0.5
250VAC
480VAC
600VAC
 8VDC 10
10
6
0.8
0.4
6
6
4
0.2
0.1
3
3
3
0.2
0.1
10
10
6
0.8
0.4
6
6
4
0.2
0.1
 14VDC
 30VDC
125VDC
250VDC

NOTES:
1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec, max.(DC)
2.Lamp load has an inrush current of 10 minutes the steady-state current, while motor load has an inrush current of 6 times the steady-state current.

CWLCA2-2
CWL Limit Switch
CWLCA12-2-Q
CWL Limit Switch

CWLCA32-41
CWL Limit Switch
CWLCL
CWL Limit Switch

CWLD
CWL Limit Switch
CWLD1
CWL Limit Switch

CWLD2
CWL Limit Switch
CWLD3
CWL Limit Switch

CWLNJ
CWL Limit Switch
CWLNJ-30
CWL Limit Switch

CWLNJ-2
CWL Limit Switch
CWLNJ-S2
CWL Limit Switch
(Visited 665 times, 1 visits today)
CWL Limit Switch